Well Inspection in the Piedmont Triad

A well inspection tells you what shape the well is in before you buy the house, or before a small problem turns into a no-water morning.

We look over the wellhead and casing, test the pump, tank, switch, gauge, and wiring, and measure how much water the well gives and how it recovers. Then we explain it in plain words.

Inspections for home buyers and for owners who want a checkup

Inspection calls tend to come from two directions.

The first is a house sale. If you are buying a home on a well, you are buying the well too: the hole in the ground, the pump hanging in it, the tank in the basement, and whatever condition all of it is in. A well inspection is how you learn that while the seller still owns it.

The second is an owner with no complaint at all. The water runs, the pump kicks on, nothing smells off. A yearly checkup is for the slow stuff: a tank losing its air charge, switch contacts burning a little more each month, a cap that cracked last winter. None of that announces itself.

Outside at the wellhead: cap, casing height, and grading

The wellhead is the part of the well you can see, and its job is keeping surface water out.

  • The cap. It should sit tight with every bolt in place, no cracks, and an intact screen on the vent.
  • Casing height. Rules in both North Carolina and Virginia put the top of the casing at least 12 inches above grade. Mulch beds and fill dirt added over the years can quietly bury a casing that once met the rule.
  • The casing itself. Cracks, dents, rust-through on old steel, and a loose fit where the electrical conduit enters.
  • Grading. The ground should slope so rainwater runs away from the well. A low spot that holds a puddle against the casing is a direct path into the water.

The EPA's advice to well owners reads like the same checklist: watch for casing that is cracked, corroded, or damaged, a cap that is broken or gone, and a surface seal that has settled or split. It also warns against ever cutting the casing off below the ground. A well that sits in a pit or under a slab gets noted in the report, because it is hard to keep sealed.

Inside: the pressure tank, switch, gauge, pump, and wiring

Most of what makes a well work sits between the wellhead and the first tap in the house. We test each piece while the system runs.

Pressure tank

Power off, pressure at zero, we check the air charge at the valve on top of the tank. It should be about 2 psi below the switch cut-in pressure. When that air leaks away or the bladder fails, the tank floods and the pump fires up for nearly every glass you draw. Pumps and switches wear out early that way.

Pressure switch and gauge

We watch the gauge as pressure falls to cut-in and climbs to cut-out, then compare those numbers with the switch setting, often 30/50 or 40/60. We look at the contacts for pitting and at the short nipple the switch sits on, which can pack solid with rust. Gauges stick and drift, so yours gets checked against a test gauge.

Pump and wiring

A submersible pump is out of sight, but we can measure the current it draws and how long it runs to refill the tank. On a three-wire system we look over the control box. Then we follow the wiring from the breaker out toward the well, looking for scorched terminals and splices left open to the weather. Old lightning hits tend to leave their marks here.

This is our side of the job. Keep the switch cover and the control box closed; they carry live power.

Drawdown and recovery testing in plain terms

A sound pump can sit on a well that cannot keep up. This test finds that out.

First we take off the cap and lower a water-level meter, a marked tape with a sensor on the end, down beside the drop pipe to find where the water sits at rest. Then we run water out of the system at a steady, measured rate, roughly what a busy morning of showers and laundry would pull. As the pump works, the water in the hole goes down. If it falls a bit and then holds, the rock is feeding water in as quickly as the pump takes it out. If it keeps falling, it is not.

Then we shut the water off and time how the level comes back. That is the recovery. A well that recovers slowly can still serve a household, because the borehole stores water between uses, but you want to know that before you plan on a garden, a pool, or a family of six.

Piedmont wells are drilled into bedrock and draw water from cracks in the rock, so yield varies a lot, even between next-door neighbors. The test tells you about this well, not the street.

What the written report tells a buyer

You get the findings in writing, in plain English. A buyer's report covers:

  • Whether the wellhead meets the 12-inch casing rule and keeps surface water out
  • How the pump performed under load, and any sign that it is wearing out
  • The condition of the tank, switch, gauge, and wiring
  • The resting water level, how far it dropped during the test, and how it recovered
  • What needs fixing now, what to keep an eye on, and what is fine

That last item is the one buyers lean on. A cracked cap is a small repair. A pump drawing high current and running long is a bigger conversation. A well that falls behind during the test is the biggest one, and it belongs on the table while the sale is still open.

Why an inspection should go with a lab water test

An inspection tells you how the well works. It says nothing about what is in the water, and the two problems most worth worrying about, bacteria and nitrate, cannot be seen or tasted. Only a lab finds them.

North Carolina's health department names the usual ways coliform bacteria and E. coli reach well water: poor construction, cracks, and missing seals. That is why the two belong together. If the inspection turns up a loose cap or a cracked casing and the lab finds bacteria, you already know where to start. We can pull the sample on the same visit, get it to a certified lab, and go over the results with you when they come back.

Once a year, even when nothing seems wrong

The National Ground Water Association wants every well looked at once a year by someone licensed or certified to do it. Its checklist lines up with ours: a flow test, a look at how the pump motor is performing, the pressure tank and switch, the rest of the equipment, and a water test for coliform bacteria and nitrates. The association also tells owners to check that the casing sticks up at least 12 inches and that the cap is secure.

North Carolina's health department adds one job any owner can handle between visits: once a year, walk out and look at the wellhead for cracks or openings. No tools needed. Look, but leave it closed.

What a well nobody checks can turn into

Most well trouble builds for months before anyone notices. A tank that loses a little air each month adds pump starts, and every start puts heat in the motor and an arc across the switch contacts. Sooner or later one of them gives out, and it never picks a convenient day.

A cracked cap or a casing buried under mulch lets rainwater and insects into the well. The water can look fine for months while bacteria settle in. By the time a test comes back positive or someone in the house gets sick, the well needs disinfecting and the opening still has to be fixed.

A buyer faces a different risk. A well that keeps up during a spring showing may fall behind in a dry August with a full household on it. Once the deed is signed, that shortfall belongs to you.

What to expect on inspection day

Call (336) 613-4314 and we will set up a time. The office keeps weekday hours, 8am to 5pm. Weekends, call or text. For a sale, give us the closing date.

The house needs power and the well needs to be in service. If the breaker has been off for months, say so up front. A pump that has sat idle sometimes does not like being woken up, and we would rather find that out with you there.

We start outside at the wellhead, move to the tank and switch, and then set up the drawdown test, which takes the longest because it cannot be rushed. If you ordered a water sample, it gets taken before anything else disturbs the system. Before we leave, we tell you what we found. The written report follows.

What is down there, and what can go wrong

Tap a part, or pick one from the numbered list, to see what it does. Press "Run the pump" to watch the water move.

How a private well system works Cutaway of a drilled well: cap and casing above the ground, a pitless adapter below the frost line, a submersible pump hanging in water-bearing bedrock, and a buried line to the house where the pressure tank, pressure switch, control box and treatment sit. TOPSOIL RED CLAY AND WEATHERED ROCK BEDROCK frost line water level
  1. A sealed, vented cap keeps out rain, insects and small animals. A cracked or loose cap is one of the easiest ways for bacteria to get into a well.

    Well Repair, Casing Repair and Well Liners
  2. Pipe that lines the top of the well and seals it from surface water and loose soil. It should stand above the ground, never be buried.

    Well Repair, Casing Repair and Well Liners
  3. The fitting on the side of the casing, below the frost line, where the water line leaves the well for the house.

    Well Pump Troubleshooting and Repair
  4. Sits down in the water and pushes it up to the house. Most drilled wells use one. Shallow wells and some older systems use a jet pump above ground instead.

    Well Pump Installation and Replacement
  5. Carries water up and power down. A split pipe or a bad splice can look exactly like a dead pump.

    Well Pump Troubleshooting and Repair
  6. In the Piedmont, wells draw water from cracks in the bedrock. Hydrofracturing can open more of them in a well that gives too little.

    Well Rehabilitation and Hydrofracturing
  7. Holds water under air pressure so the pump does not start every time you open a tap. A tank that has lost its air makes the pump short cycle.

    Pressure Tank Installation, Replacement and Tuning
  8. Turns the pump on at the low setting and off at the high one. Pitted contacts or a clogged sensing tube stop the whole system.

    Pressure Switch, Control Box and Wiring Repair
  9. Three-wire pumps have a control box on the wall with the start parts. Two-wire pumps do not.

    Pressure Switch, Control Box and Wiring Repair
  10. Filters, softeners and disinfection go after the tank. A lab test tells you which one, if any, you need.

    Well Water Treatment Systems

Well Inspection: common questions

Still stuck? (336) 613-4314

Doesn't a regular home inspection already cover the well?

Usually only in part. Many home inspectors note the tank, the gauge reading, and whether the taps run, then recommend a well specialist. They do not open the well, measure the water level, or run a yield test. Read the scope section of your inspection agreement. If the well is excluded or barely mentioned, book a separate well inspection before your due diligence period runs out.

Should a seller get the well inspected before listing the house?

It can save a sale. A pre-listing inspection lets you fix a cracked cap, a waterlogged tank, or a buried casing when it suits you rather than under a buyer's deadline. If the well comes up short on the yield test, you would rather know that before the first showing than in the middle of a contract.

Is the inspection any different for a jet pump?

A little. A jet pump lives above ground, usually in the house or a pump shed, so we can see and hear it run, check the seals for leaks, and confirm it holds its prime. A submersible pump hangs down in the well, so we judge it by what we can measure at the surface. The wellhead, tank, switch, wiring, and drawdown testing are the same either way.

What if the inspection finds a problem?

You get a straight answer about how serious it is and what fixing it involves. Many findings, like a loose cap, a tank that needs its air charge set, or a worn pressure switch, are routine repairs we handle. Bigger items, like low yield or damaged casing, get explained with the options laid out. A buyer ends up with something specific to bring to the seller.

What happens if the casing is below ground level?

It gets flagged. Both states require at least 12 inches of casing showing above the ground, and a buried or cut-off casing gives surface water an easy path to the top of the well. In many cases the casing can be extended upward. In Virginia, extending casing above ground is not treated as a well alteration under the permit rules.

Will the inspection tell me how many years the pump has left?

No honest inspection can give you a date. What it can tell you is how the pump is doing right now: the current it draws, how long it runs to fill the tank, whether the pressure holds, and whether anything looks or sounds wrong. A pump working well within its limits has margin. One drawing high current or running constantly is telling you to plan ahead.

Do you inspect wells in Virginia too?

Yes. We hold a Virginia water well license and a North Carolina well contractor certification, and our service area runs from the North Carolina Piedmont into Southside Virginia. The inspection is the same in both states, and the report points out any rule that differs.

How long does the drawdown part take?

It depends on the well. We run water until the level settles at a steady point, or until it is clear that it will not, and then we watch the recovery. A strong well settles early. A weak one takes longer, and that slower reading is often the most useful thing a buyer learns.

Good references

Official pages we point homeowners to. They open in a new tab.

No water, low pressure or bad taste?

Call or text. Monday to Friday, 8am to 5pm. Saturday and Sunday: call or text.