Most no-water calls trace back to a short list of causes, and a few minutes of looking can tell you, and us, which one you are facing. Piedmont Well and Water Services handles emergency well service across the Piedmont Triad and Southside Virginia.
Two more things to think about
The checklist above covers the faucets, the breaker, and the gauge. Two more things are worth a minute before you call.
Recent heavy use. A hose left running, a pool being filled, a sprinkler on a timer, or a houseful of guests can pull a well down faster than it refills. If that fits, turn the pump breaker off and let the well rest before you assume the pump has failed. The section on low wells below explains what to watch for.
The weather. Lightning and power surges are common causes of failed pumps and control boxes, and that damage does not always trip a breaker. A storm the night before is worth mentioning when you call.
What not to do while the water is off
A dry house tempts people into fixes that make things worse or get someone hurt. Leave these alone.
- Do not keep resetting the breaker. One reset is fine. If it trips again, something is shorted or the motor is locked, and every reset sends a heavy jolt of current through a part that is already failing.
- Do not open the pressure switch, the control box, or the well cap. The switch and control box carry line voltage under their covers. The cap keeps insects, dirt, and rain out of your drinking water.
- Do not tap on the pressure switch. Knocking a stuck switch with a screwdriver handle is an old trick. It sometimes works once. It is also how people get shocked.
- Do not run the pump dry. If the pump seems to be running (you hear it, or the switch has clicked on) but the gauge will not climb, turn the breaker off. A pump with no water around it to cool it can burn up.
- Do not pour water down the well. It will not prime a submersible pump, and it can carry contamination in.
The usual causes, most likely first
No-water calls tend to come down to the same handful of causes, listed here roughly from most likely to least.
- Power and lightning. A tripped breaker, a blown fuse, a loose wire, or a surge that damaged the switch, control box, or pump motor.
- The pressure switch. Its contacts burn, pit, or stick after years of starts. The little sensing tube beneath it can clog with sediment or iron, so it never senses low pressure. Ants also like to nest under the cover and jam the contacts.
- The control box. Three-wire submersible pumps have a control box mounted near the tank. The capacitor or relay inside can fail, often after lightning, and the pump will not start even with power reaching it.
- The pump. Motors wear out, windings fail, and a pump that has been short cycling or running dry may simply quit. A splice on the pump cable can fail, too, and a jet pump can lose its prime and spin without moving water.
- The drop pipe. The pipe that carries water up from a submersible pump can split or pull apart at a joint. The pump runs, but the water pours back into the well instead of reaching the tank.
- The well level. During a dry spell, or after very heavy use, the water can drop below the pump's intake. The pump is fine. It just has nothing to pull from until the well recovers.
When the well runs low instead of the pump failing
Piedmont wells are drilled into hard rock, and according to the USGS, that bedrock passes water mainly along its fractures, under a cover of weathered rock and soil. How much water you get comes down to the water-bearing cracks your well happens to cross. Some wells simply refill slowly.
A well that ran low usually leaves clues. The water may have sputtered, spit air, or turned cloudy just before it quit. It tends to happen after a long stretch of watering or washing, or late in a dry summer. Sometimes a little water comes back after the system sits, then runs out again with use.
If that matches what you saw, let the well rest with the breaker off. Water that returns after resting usually means the pump still works and the well itself needs a closer look. We can measure how the level drops and recovers under pumping, then talk through options such as setting the pump deeper, rehabilitation, or hydrofracturing.
Why a no-water problem rarely stays the same size
Waiting it out is tempting. Most no-water problems do not hold still, though.
A pump that has lost its water keeps trying to run whenever the switch calls for it, and every minute dry heats the motor. A switch with welded contacts can keep a pump running nonstop against a split drop pipe. A breaker that someone keeps resetting cooks the motor windings a little more each time. What started as a burned switch or a bad capacitor turns into a pump coming out of the well.
The house suffers too. In a cold snap, pipes in a well house or crawlspace with no water moving through them freeze more easily, and a cracked fitting stacks a second problem on the first. Meanwhile the household is hauling water in buckets, which is hardest on older folks, small children, and animals.
Calling early, even just to describe what you are seeing, keeps a small repair from growing.
What to tell us when you call
A clear description lets us arrive with the right parts in mind. Before you call (336) 613-4314 for emergency well service, have these answers ready if you can:
- Whether the whole house is out, or just one spot.
- What the pressure gauge reads, and whether the breaker tripped or was reset.
- Whether the pump is down in the well (submersible) or above ground in a basement, crawlspace, or well house (jet pump), if you know.
- Anything that happened first: a thunderstorm, an outage, heavy watering, digging in the yard, or recent work on the system.
- What you heard or saw: clicking, humming, sputtering, air, or muddy water.
- Where the well and tank are, plus anything about access, like a locked gate, a tight crawlspace, or dogs in the yard.
We keep office hours Monday to Friday, 8am to 5pm, and run the schedule from there. Saturday and Sunday, you can call or text. Put those details in your message so nothing has to be asked twice.
What happens when we get to your well
We work from the easy checks to the hard ones, and nothing gets pulled from the well until the readings say so.
- We start with what you saw. Your notes on the gauge, breaker, and weather point us in a direction.
- We check power with a meter at the breaker, the switch, and the control box.
- We test the switch and control box. Contacts, the pressure-sensing tube, the capacitor, and the relay all get checked. Plenty of no-water calls end right here, with a part replaced at the surface.
- We read the pump from the surface. Amperage and resistance readings on the pump wires tell us if the motor is drawing normally, locked, shorted, or open.
- We explain before we pull or replace anything. You hear what we found and what the choices are.
- If the meter says the trouble is below ground, the pump comes up. The cap comes off, and the pump rises with its drop pipe and cable still attached. We inspect the pipe, the splice, and the pitless adapter, and replace what failed.
- We disinfect, set the pressure, and watch it run. We check the tank charge and switch settings and let the system cycle until it behaves.
Getting safe water back after the repair
Water flowing again is not the same as water ready to drink. Pulling or replacing a pump means opening the well, and whatever rode down on the pipe and cable is now in your water.
Under North Carolina's well rules, disinfection is required of anyone who installs, repairs, maintains, or tests a pump. The rule sets a floor: a chlorine level of at least 100 parts per million in the well, left standing 24 hours or longer, then pumping until no chlorine can be detected before the water goes back into use. Virginia's rules also call for disinfection after work that requires getting inside the casing.
Plan on bottled water for drinking and cooking until the chlorine is gone. Softeners and filters should be bypassed while chlorine is in the lines. The chlorinated water is run out through an outdoor spigot rather than the house, which also carries off air and any grit the work stirred up.
After that, get the water tested. NC DHHS, the state health department, recommends testing after any repair or replacement of a well component, because opening a well gives contaminants a way in. We can run the test and explain the lab results in plain language.