If the pump clicks on every time someone rinses a glass, the pressure tank has probably lost its air charge or torn its bladder.

Map: Summerfield, NC in relation to GreensboroSummerfieldGreensboro11.1 miStokesdaleOak RidgeColfaxGUILFORD
Town
Summerfield, NC
County
Guilford County
From our Greensboro office
11.1 miles, straight line
Open Summerfield in Google Maps

The pump then starts and stops far more than it should, and every extra start wears on the motor. Pressure tank replacement Summerfield owners schedule early is a much smaller job than a pump that burns out later.

The air cushion between your pump and your taps

The pressure tank is the cushion between your pump and your taps. Inside a modern tank, a rubber bladder or diaphragm keeps the water apart from a pocket of compressed air. As the pump fills the tank, that air squeezes tighter. When you open a tap, the air pushes water out, so the pump can stay off until pressure falls to the cut-in setting on the switch.

Once the bladder tears or the air leaks away, the tank fills solid with water and the cushion is gone. Every small draw drops pressure straight to cut-in, and the pump starts. Replacing the tank means draining the system, disconnecting the old tank at the tank tee, and setting a new one sized for your pump and your household, with its air charge matched to the switch.

The parts around the tank get a look too: the gauge, the pressure relief valve, the drain valve, and the switch. A tank swap is a good time to replace a pitted switch, since the two work as a pair. None of this opens the well, which makes it a different kind of job from a pump pull.

Why a pressure tank replacement Summerfield owners put off ends up hurting the pump

Once the tank stops cushioning, the pump and switch take every hit. The pump may start several times a minute while a shower runs. Each start heats the motor and arcs the switch contacts, and both wear out long before they should.

Older steel tanks add a second problem. When rust works through the shell, the tank can weep or split, and the water ends up on a garage floor, in a crawlspace, or soaking into a basement wall. Shower pressure that pulses strong and weak is the daily annoyance. A pump that quits years early is the bigger one.

A switch that has chattered against a dead tank for months can also stick closed. Then the pump keeps building pressure until the relief valve opens, and whatever room the tank sits in gets wet.

Telling a tank problem from a pump problem

  • Rapid clicking. The switch cuts in and out every few seconds while one tap runs.
  • A jumpy gauge. The needle drops from cut-out to cut-in almost as soon as water starts flowing.
  • Water at the air valve. When the tank's air valve is checked, water comes out instead of air, which means the bladder has failed.
  • A solid sound. Knock on a healthy tank and the top half sounds hollow. A waterlogged one sounds full all the way up.
  • Rust and sweat. Rust streaks, a damp floor, or a weeping seam on an older steel tank.
  • Pulsing showers. Pressure surges and sags in time with the pump.

If the pump runs steadily, the tank checks out, and pressure is still low, the cause is more likely the pump, the switch setting, or the well. That calls for a different kind of visit.

Our tank swap, one step at a time

  1. We confirm the tank is the problem by checking its pre-charge and watching how the system cycles.
  2. We shut off power to the pump at the breaker and drain the system down.
  3. The old tank is disconnected at the tank tee and moved out of the way.
  4. We check the new tank's pre-charge and set it about 2 psi under the switch's cut-in pressure.
  5. The new tank goes in with the gauge, relief valve, and drain reconnected, plus a new switch if the old one is pitted.
  6. We restore power, let the pump fill the tank, and watch several full cycles to confirm cut-in and cut-out land where they should.
  7. Every joint gets checked for leaks, and we show you how to read the gauge so you can spot trouble early next time.

Nothing on this list touches the well itself, so there is no well cap to open and no chlorine to run out afterward.

Low-density lots and community wells in Summerfield

In the town's Residential district, gross density tops out at 1.0 unit per acre, and the ordinance expects homes there to run on wells or community wells, with septic systems or community sewage treatment. For a house on its own well, the pressure tank is the only stored water the household has. When it fails, nothing sits behind it.

Community wells change the setup. The town's 2010 plan cites a 2007 report from the Guilford County health department finding that many community wells using more than 10,000 gallons a day had been put in to serve new developments across northwestern Guilford, this town among them. Those systems have their own pumps and equipment, so a house on one may have a small tank of its own or none at all. We work on private residential wells, so expect a question about which kind you have when you call.

Where the tank sits in your house affects the job as well. A tank in a garage or basement is easy to reach. One tucked into a crawlspace or a pump house takes more care to drain and swap, and a tank in an unheated space needs protection from hard freezes. If yours sits in a pump house away from the main house, tell us ahead of time so we can plan the work.

Booking a pressure tank visit

We handle scheduling at the office weekdays from 8am to 5pm. Call or text (336) 613-4314, and weekends work the same way. If you can, read us the tank gauge as the pump starts and again as it stops, since those two numbers tell us a lot. If the tank is the original one that came with the house, mention it, because its age hints at what we will find. We often come in on NC 150 when heading to your part of Summerfield.

ZIP code we cover around Summerfield: 27358.

Questions from Summerfield

Still stuck? (336) 613-4314

Does replacing a pressure tank need a permit?

No. North Carolina law does not call for a repair permit to replace a well tank or pump, and a tank swap never opens the well seal. Permits come into play for work on the well itself, like casing repair or a new well. If we see a problem at the wellhead while we are at your house, we will point it out and explain the options.

Our Summerfield subdivision runs on a community well. Do we have our own tank?

Maybe. It depends on how the system was built. Check the garage, the crawlspace, or a utility closet for a tank with a pressure gauge and a switch near it. If you find one, it works just like a private-well tank and can be replaced the same way. If there is no tank and no switch, the community system supplies your pressure, and its operator handles tank problems.

Who keeps watch over the big community well systems in Guilford County?

Wells or well systems using more than 10,000 gallons a day need their own county application, with a site plan, a pumping test of at least 24 hours, and a bacteria analysis by the health department. Whoever owns or runs the system answers for its pumps and tanks. If your house is on one and the pressure is off, start with them.

Will the town's planned fire flow tank change our water pressure?

No. The project the town sought bids on in 2026, a 150,000-gallon storage tank with a supply well, is meant for fire protection, not household service. It is not set up to supply homes. Your well pump and pressure tank keep doing the same job they always have, so a healthy tank is still worth keeping up.

Can I just add air rather than buy a new tank?

Sometimes. If the bladder is intact and the tank has slowly lost pre-charge, resetting the air can bring it back. The pump has to be off and the tank drained first for the reading to mean anything. If you press the air valve and get water, the bladder is torn and air will not stay, so the tank needs replacing.

Will a larger tank give us better water pressure?

No. The switch sets the pressure, not the tank. A bigger tank stores more water between cut-in and cut-out, so the pump runs longer and starts less often, which is easier on the motor. If pressure feels weak, the fix is usually a switch setting, a clogged filter, or a pump problem.

Why is there water on the floor around our tank?

The usual sources are a rusted-through steel tank, a leaking fitting at the tank tee, or a relief valve that opens because the switch is not shutting the pump off. That last one means a stuck switch and needs attention right away. If water keeps coming, shut off the pump breaker and call us.

How often should a pressure tank be checked?

Once a year is a good habit. The National Ground Water Association recommends a yearly checkup by a well professional that covers the pressure tank and switch along with the pump and the water. Between visits, notice whether the pump starts more often than it used to, since that is usually the first sign the tank is losing air.

Good references

Official pages we point homeowners to. They open in a new tab.

No water, low pressure or bad taste?